11
2.6 Function as Current Controller
In the case the device was not ordered as current controller, the adjustment ex factory is
"Speed control".
In some applications it may be useful to operate the TBF amplifier as a pure current
controller, because a torque control is desired or the speed controller in the master control
is already realized.
To set the amplifier to current control or speed control set the three soldering jumpers JP9,
JP10 and JP11 (see figure) as follows:
JP9.1 to JP9.2 JP10.1 to JP10.2 JP11.1 to JP11.2
Speed control closed closed open
Current control open open closed
Numbering of the soldering jumpers is as follows: e.g. for JP9: JP9.1= right field of the
soldering jumper, JP9.2= left field of the soldering jumper.
Speed control Current control
+
JP 11
S T RO M
JP 1 0
DR E HZ .
PC -T B F / 2( S T R-D R Z )
Figure 3: Jumper Settings